Subversion Repositories svn.mios

Compare Revisions

Ignore whitespace Rev 1186 → Rev 1187

/trunk/ucapps/midibox_seq_manual_hw.html.gen
261,6 → 261,42
 
<P><CENTER><IMG SRC="mbhp/mbhp_line_driver_aout_ng.jpg" width=550 height=348></CENTER></P>
 
<P CLASS=DESC>Here a MBSEQ_HW.V4 configuration example which works with the MBSEQ Frontpanel PCB:
<TT><PRE style="margin-left:20px">
##################################################
# CV and Gate/Trigger/Sync Setup
##################################################
 
# the 8 CV gates can be assigned to a shift register (0=off, 1-32: number of shift register):
# - 1st CV Gate available at DOUT SR output D7
# - 2nd CV Gate available at DOUT SR output D6
# - 3rd CV Gate available at DOUT SR output D5
# - ...
# - 8th CV Gate available at DOUT SR output D0
CV_GATE_SR1 3
 
# and DIN Clock Outputs can be assigned to a shift register as well (0=off, 1-32: number of shift register):
# D7..D0 will output individual clock or start/stop signals which can be configured in the CV configuration page
CLK_SR 4
 
# additional gate triggers are available on common digital output pins of the
# DOUT shift register chain - they are assigned to AOUT channel #16 (Note C-1, C#1, D-1, ...)
# define the shift registers which should be used here (each provides 8 gates)
# Note that SRs assigned to this function cannot be used as LED outputs (exclusive function)
# Allowed values: 1-32, 0 disables the function, all other values invalid and not allowed
DOUT_GATE_SR1 5
DOUT_GATE_SR2 6
DOUT_GATE_SR3 0
DOUT_GATE_SR4 0
DOUT_GATE_SR5 0
DOUT_GATE_SR6 0
DOUT_GATE_SR7 0
DOUT_GATE_SR8 0
</PRE></TT></P>
 
<P CLASS=DESC>The gates are available at the 3rd DOUT shift register, the clocks at the 4th DOUT shift register, and additional gates/drum triggers at the 5th and 7th DOUT shift registers. This works, since Wilba's Frontpanel PCB only uses two DOUT shift registers; a MBHP_DOUTX4 module connected to J2 of the PCB will represent SR 3, 4, 5 and 6.<BR>
If more gates are required, just add another MBHP_DOUTX4 module and assign the number 7..10 to DOUT_GATE_SR3..6 accordingly.</P>
 
<H2> <IMG SRC="images/bullet.gif" ALT=""> Ethernet Interface </H2>
 
<P CLASS=DESC>An Ethernet port can be optionally added to send and receive OSC messages. It requires a <A HREF="mbhp_eth.html">MBHP_ETH</A> module. Details about the possibilities are explained <A HREF="midibox_osc.html">at this page</A>.</P>